• 【药品名称】通用名称:止血贴 
    商品名称:STEPTY-P 
    英文名称:HEMOSTATIC BANDAGE 
    汉语拼音:ZhiXieTie
  • 【成份】产品组成:垫,胶带,加压板。规格:胶带部:40 mm×120mm,垫部分:27mm×15mm(厚约9mm),加压板:36mm×30mm .一次性使用无菌产品。
  • 【适应症】动脉压测定、血气检测用于足背动脉及桡动脉穿刺部位止血覆盖。
  • 【规格】No.120P
  • 【批准文号】国食药监械(进)字2011第2640417号(更)

https://www.nichiban.com/medical/puncture_protection/stepty_p/

A composite pad consisting of a 9mm thick pad and a plate provides high hemostatic effect.

Individually sterilized package

Stick-on time label

Pad that effectively transmits pressure to the skin
Stick-on time label to prevent excessively long use of the product
Example of application to the radial artery
Example of application to the dorsal pedis artery

Relationship between tape elongation and pressing force of “STEPTY™ P”

The compression force increases with the length of the stretched polyurethane nonwoven adhesive tape. By applying both sides of the tape approximately 2cm apart, the necessary compression force for hemostasis was obtained (approximately 100mmHg), which was maintained approximately 80% of the initial value even 1 hour after application.

Thermograph of palms with STEPTY™ P attached

The palms before application and after two hours of application of STEPTY™ P were compared. There was no difference in skin surface temperature, and no decrease in blood flow was observed.

https://youtube.com/watch?v=jtJlG_75qt4%3Frel%3D0
  1. 1Take out the STEPTY™ P from its pack, then squeeze recessed points in the center of the plastic plate with your fingertips for easy identification of the location of the pad.
  2. 2Place the pad so that it covers the point of entry into both the skin and the blood vessel, then hold the pad down with the thumb while removing the indwelling needle. When using a metal needle, be sure to attach STEPTY™ P following withdrawal of the needle.
  3. 3As you pull out the needle or catheter, put firm pressure on the upper surface (back) of the pad with your finger, and partly peel off the liner on the ulnar side of the arm.
  4. 4While pressing down on the pad firmly, stretch the tape on the ulnar side about 2 cm.
  5. 5Continue to apply firm pressure on the pad as you stick the tape securely onto the skin. Then peel off the rest of the liner and attach the tape.
  6. 6Switch thumbs while continuing to press firmly on the pad, making sure it stays in place.
  7. 7While continuing to apply pressure on the pad, peel off the other liner halfway in the same way as the first, stretch the tape about 2 cm, attach it firmly to the skin, and then peel off the remaining liner and attach the tape.
  8. 8Write the time applied on the label and then stick it on top (back) of the pad. Normally, the bleeding will stop in about 1 hour after “STEPTY™ P” is applied. Remove it within 2 hours following application because hemostatic performance varies from person to person and sometimes bleeding resumes.
  • Hemostasis and protective covering after puncture of radial artery or dorsal pedis artery in invasive arterial pressure measurement, blood gas measurement, etc.

Reuse prohibited

  • If the wound becomes clinically infected while using the product, stop its use and conduct appropriate treatment.
  • If symptoms appear to be skin disorder (rash / redness, blisters, skin peeling, itchiness, etc.) on the application site, discontinue use and take appropriate treatment.
  • Be sure to remove the needle before applying this product to avoid damage to the blood vessel and skin.
  • Stretching the tape beyond the length required for compression will cause excessive pulling of the skin and may cause skin irritation.
  • To avoid skin irritation as much as possible, remove this product within 2 hours of its application.
  • The product should always be removed by a doctor or a nurse after use.
  • When removing this product, make sure that there is no bleeding for several minutes while resting and that hemostasis is formed. If hemostasis is insufficient, take appropriate measures such as manual pressure hemostasis.
  • After removal, protect the puncture area with covering protection to prevent infection.
  • If the product gets wet or soiled during use, take it off and apply a fresh pad immediately.
  • Do not use the product if the packaging is dirty, damaged or wet.
  • Use the product immediately after breaking the seal.
  • When removing the pad, peel it off slowly along the flow of the body hair to prevent skin damage.
  • Store at room temperature, away from water, high temperatures, high humidity and direct sunlight.
Product numberSizePer box
Tape areaPad area (9mm thick)Plate area
No.120P40mm x 120mm27mm x 15mm36mm x 30mm30 sheets